Charge Mode Accelerometer Portable Calibrator

Create Calibration Certificates for Vibration Instrumentation | Model C9110D-T

Optimized for vibration transducers found in research & development, automotive, aerospace, and general testing applications, Charge Mode Portable Vibration Calibrator Model C9110D-T is a traceable calibration system in a mobile package. The powerful shaker supports calibration of ICP® (IEPE), piezoelectric charge, piezoresistive (PR), modulated current (CVLD), and variable capacitance accelerometers over a broadband frequency range from 5 Hz to 10 kHz.

CE| UKCA

Highlights

  • Create Calibration Certificates for Vibration Instrumentation
  • Mobile, Lightweight Design with Long Battery Life
  • Stepped Sine Tests with Pass/Fail
  • Popular Mounting Accessories Included
  • Open Programming via SCPI Commands

Applications

  • On-site Calibration of Vibration Instrumentation
  • Troubleshooting Vibration Test Beds
  • In-situ Testing & Confirmation of Accelerometer Sensitivity

On-Site Accelerometer Sensitivity Measurement & Traceable Calibration Reports

Model C9110D-T is a turnkey calibration solution, supplied with mounting adapters necessary to support the most common test & measurement sensors on the market. The device creates accelerometer calibration reports traceable to NIST and PTB per the ISO 16063-21 standard. Reports are fully customizable and compliant to ISO 17025. A built-in sensitivity display assists with on-site troubleshooting of vibration test beds and data acquisition. An integral precision quartz reference accelerometer and closed-loop level control gives the C9110D-T enhanced accuracy and stability. The device is packaged in a rugged Pelican® Storm case.

CALROUTE firmware allows engineers to program calibration routines with pass/fail tolerances for both frequency response and linearity. The shaker provides feedback to technicians after each test point. Model C9110D-T supports programming calibration tolerances – including asymmetric bounds – either per ISO 16063-21 or by simply programming hard limits.

Programming and data exchange is done on any computer with Microsoft Excel®. No other software is required. As an option, The Modal Shop offers calibration software that supports automated accelerometer calibration and databasing, utilizing the shaker and reference accelerometer within the C9110-T.

The C9110D-T is supplied with an accuracy calibration certificate. Calibration of the C9110D-T is accredited to the ISO 17025 standard by the American Association of Laboratory Accreditation (A2LA).


Specifications

View Datasheet | View Specification Sheet

USMetric
Frequency Range (operating) [1]5 Hz to 10 kHz300 to 600k CPM
Maximum Amplitude (50 Hz, 10-gram payload)20 g pk196 m/s² pk
Accuracy of Displayed Acceleration & Sensitivity Readout (10 Hz to 10 kHz) [2] [3]±3 %
Operating Battery Life [4]18 hours
Weight18 lb8.2 kg
Sensor Mounting Platform Thread Size¼-28

[1] 100-gram payload
[2] Measured with 10-gram quartz reference accelerometer
[3] Calculated by measuring the % difference between the known sensitivity of a reference accelerometer as calibrated by laser primary system per ISO 16063-11 and the measured sensitivity of same reference accelerometer when tested at the same points
[4] As shipped from factory in new condition and measured at 100 Hz, 1 g pk with 100-gram payload

Accessories

For a more comprehensive list of accessories, please see the Product Specification Sheet.

ModelDescription
Included
081B20¼-28 to ¼-28 Adaptor
081A0810-32 to ¼-28 Adaptor
9100-CAL01NIST Traceable Certificate of Calibration,Accredited to ISO 17025 by A2LA
9110-USBUSB Flash Memory Drive: Loaded with Calibration Report Generation Workbook
9155-MNT055-40 F to ¼-28 M Mounting Pad
9155-MNT0610-32 F to ¼-28 M Mounting Pad
9155-MNT07Adhesive Mounting Plate to ¼-28 M
Calibration Report Generation WorkbookCertificates Generated Via 9110D Memory: Frequency Response & Linearity for AC Voltage & Current Output Transducers
Certificates Generated Via User-Input: Vibration analyzer/meter linearity & frequency response accuracy, linearity for 4-20 mA vibration transmitters, proximity probe curves (gap vs. DC voltage)
Warranty2 Years, Inclusive of Drift/Accuracy
Optional
9100-MNTKITMounting accessory kit for 9100 Series Portable Vibration Calibrators, to adapt to ¼-28 threaded mounting platforms. Includes studs/inserts (¼-28, 10-32, 6-32 and 5-40) and bases (for adhesive, magnetic and custom thread patterns).
9100-PRPiezoresistive accelerometer calibration kit for Portable Vibration Calibrators. Includes Endevco model 4418 signal conditioner, connection cable with push terminal inputs, and mounting plate
081A27Mounting stud, 5-40 to 5-40 threads, without shoulder, BeCu
9155-MNT32Thread adaptor, 10-32 internal thread x ¼-28 external thread, BeCu
9155-MNT38Thread adaptor, 6-32 internal thread x ¼-28 external thread, stainless steel
080A90Loctite 454 - Quick bond Gel (for use with accelerometer adhesive mounting bases to fill gaps on rough surfaces)
9155-MNT01Calibration System Mounting Adaptor. For Sensors with triangular hole patterns on 1.20" diamter circle. Uses an 8-32 mounting thread. Includes 3 mounting scews. For use on 10-32 and ¼-28 shakers
9155-MNT02Calibration System Mounting Adaptor, for sensors with triangular hole patterns on a 1.00" diameter circle. Uses a 4-40 mounting thread. Includes mounting screws. For use on 10-32 and ¼-28 shaker inserts.
9155-MNT03Calibration System Mounting Adaptor, for sensors with square hole patterns on a 1.375" diameter circle. Uses a 6-32 mounting thread. Includes mounting screws. For use on 10-32 and ¼-28 shaker inserts
9155-MNT18Calibration System Mounting Adaptor. For Sensors with 2 or 4 holes on 0.300 diamter circle. Uses a 0-80 mounting thread. Includes mounting screws for use on 10/32 and ¼-28 references
9155-MNT19Calibration System Mounting Adaptor. For sensors with a triangular hole pattern on a 1.190" (30.2 mm) diameter circle. Uses an M4 mounting thread. Includes 3 mounting screws. For use on 10-32 and ¼-28 shakers
9155-MNT52Calibration System Mounting Adaptor. For sensors with 8-32 through hole mounting. Includes mounting screws. For use on ¼-28 shakers only
9155-MNT08Calibration System Mounting Adaptor. For Sensors with 6-32 through hole mounting. Includes mounting screws. For use on ¼-28 shakers only
9100-PPA01Proximity probe adaptor kit, supports 5mm and 8mm size probes. Includes brackets for securing probes with ¼ inch, ⅜ inch, 6mm, 8mm and 10mm diameter case threads. Includes Mitutoyo micrometer scaled in mils and 9100-PPA02 nickel plated AISI 4140 steel target.
9100-MPPA01Proximity probe adaptor kit, supports 5mm and 8mm size probes. Includes brackets for securing probes with 6mm, 8mm, 10mm, ¼ inch and ⅜ inch diameter case threads. Includes Mitutoyo micrometer scaled in microns and 9100-PPA02 nickel plated AISI 4140 steel target.

Support

Product Support Included with Purchase

  • NIST Traceable Certificate of Calibration, Accredited to ISO 17025 by A2LA
  • USB Flash Memory Drive: Loaded with CALROUTE Workbook
  • Certificate Generated via Unit Memory: Frequency Response & Linearity for AC Voltage Output Transducers
  • Certificate Generated Via User-Input: Vibration Analyzer/Meter Linearity & Frequency Response Accuracy, Linearity for 4-20 mA Vibration Transmitters, Proximity Probe Curves (Gap vs. DC Voltage)
  • Quickstart Guide Available in English, Chinese, French, Japanese, Polish, Russian, & German
  • 2-Year Warranty, Inclusive of Drift/Accuracy
  • Technical Training Webinars Available Upon Request, 24/7 Video Library

Sensors Supported

The C9110D-T creates ISO 17025 compliant calibration reports via ISO 16063-21 methodology for the following vibration sensor types:

  • ICP® (IEPE) Accelerometers
  • Charge Mode Transducers
  • Piezoresistive Accelerometers
  • Variable Capacitance Sensors
  • Modulated Current (CVLD) Transducers