Building Acoustics and Room Acoustics Rental

Meter | Noise Sources | Tapping Machines | Software

Reverberation time is a key parameter in a wide array of venues ranging from concert halls, performance venues, church and worship halls to healthcare and educational spaces. The Larson Davis SoundAdvisor™ Sound Level Meter Model 831C-RA offers reverberation time functionality to test T20 and T30 to ISO 3382-2 and ASTM E2235-04 measurement standards via Integrated Impulse Response (Schroeder method) and Interrupted Noise excitation methods with an automated trigger for easy control. Pink and white noise source is provided to drive omni-directional speakers.  Quality and measurement grade indicators per the ISO standard are built in.

Applications beyond RT measurements include architectural acoustics and absorption coefficient measurement in an easy to use package.


rental-831C-ra-angled-product

Reverberation Time Sound Level Meter

Larson Davis Class 1 Integrating Reverberation Time Sound Level Meter Model 831C-RA. Provides reverberation time, 1/1 and 1/3 octave, pink and white noise generation, and auto trigger.

  • T20 and T30 measurements according to ISO 3382-2:2008 and ASTM E2235-04
  • Provides 1/1 and 1/3 octave filters for computation of reverberation time
  • Supports Integrated Impulse Response and Interrupted Noise excitation methods
  • Built-in pink and white noise generator
  • Automated trigger
  • Display of RT spectrum, individual and ensemble decays
  • Quality indicators to ISO 3382-2
  • Included Utility software simplifies setup, project management, and results reporting
  • Full specs from manufacturer

Recommended Items to Rent

  • 831C Analyzer - with reverberation time firmware
  • 377B02 - 1/2" freefield microphone
  • PRM831 - 1/2" Preamplifier
  • EXC010 - Microphone extension cable, 10ft
  • KBAT15 AA - battery kit for short term use, with recharger
  • PSA029 - AC power adaptor
  • CBL138 - USB cable to connect to AC adaptor or computer
  • WS001 - 3-1/2" windscreen
  • Software Utility - software for meter setup and data download
  • Accessories - Calibration data, Manual sets, computer interface accessories and an acoustic calibrator

LD-831C-RA-G4-interruped-t30-measurement

G4 LD Utility Software

Included with your rental is this complete software package, which simplifies setup, control, and data visualization and reporting for reverberation time measurements.

Full specs from manufacturer

Dodecahedral Sound Source BAS001

Larson Davis omnidirectional (dodecahedral) source.  Generates omni-directional sound fields for making standard compliant measurements including reverberation time (ISO 3382, ASTM E2235), building acoustics including insertion loss, acoustic absorption area, (e.g., ISO 140-4 ISO 140-3, ASTM E336, ASTM E90, DIN 55 210). BAS001 is typically used to saturate a room with a uniform acoustic field. The recommended high efficiency power amplifier BAS002-U has no fan for cooling, allowing measurements in quiet environments, perfect for reverberation time applications.

Full specs from manufacturer

Rental Includes

  • Signal Cable - 5 meters long
  • CCS044 - Carrying case
  • Technical Manual

Note: TRP023 tripod ordered separately


Directional Sound Source BAS003

Larson Davis directional sound source. Generates homogeneous sound fields using random noise for making standard compliant building acoustics measurements such as insertion loss, acoustic absorption, and more (e.g. ISO 140-3, ASTM E90, ISO 140-5, ASTM E966). The BAS003 is typically used to generate a noise in a free-field for the evaluation of the transmission loss index of a façade. The available high-efficiency power amplifier, BAS002, is light and can be remotely controlled for easy use in the field.

Full specs from manufacturer

Rental Includes

  • Signal Cable - 10 meters long
  • CCS044 - Carrying Case
  • Technical Manual

Note: TRP023 tripod ordered separately


Sound Source Speaker Amplifier BAS002-U

Larson Davis 500 Watt 110-125 BAC power amplifier for BAS001 or BAS003.  Includes remote control and carrying case.

Full specs from manufacturer

Rental Includes

  • Remote Control
  • Signal Presets - USB flash drive with signal presets
  • Carrying Case
  • Technical Manual

Tapping Machine BAS004

The Larson Davis BAS004 high precision electromagnetic tapping machine is ideal for impact noise generation in buildings per ISO 140, ISO 117, DIN 52210, BS 5821, and ASTME 492. The unit's hammers are raised by an electromagnetic field allowing a frictionless 40mm drop and reduces vibrations caused by mechanically actuated systems. Dimensions of the unit are 10x5x22” (250x120x550mm), and the weight is 26lb (12kg).

Full specs from manufacturer

Rental Includes

  • BP50 - Internal battery for standalone operation
  • RC50W - Remote control
  • Soft Carrying Case

Impulsive Sound Source BAS006

The Larson Davis BAS006 is used to create impulsive noise that includes low frequency energy and avoids problems like secondary bounce. These characteristics make it an ideal choice for measuring reverberation time when the complexity and weight of a speaker and amplifier is not needed. Dimensions of the unit are 24x8x5” (610x203x127mm), and the weight is 11.4lb (5.2kg).

Full specs from manufacturer


Tapping Machine NOR277A

The NOR277A tapping machine performs impact sound transmission testing according to ISO140, part VI, VII and VIII, ASTM E-492 and ASTM E-1007. Unit has five stainless steel 500g hammers with a 40mm fall each 100mm apart.  A servo system maintains tapping frequency even during temperature changes.  The unit weighs less than 22lbs (10kg) and has a level gauge to aid user when adjusting fall height.  A self-check feedback loop is included: an LED status for each hammer is located on the front panel, and indicates when the impact velocity and tapping frequency meets standards.

Full specs from manufacturer

Rental Includes

  • Battery - Internal battery for standalone operation
  • AC Power Cord
  • Remote Control
  • NOR1336 - Soft carrying case
  • User Manual

Bruel & Kjaer Type 4204

Type 4204 is a calibrated reference sound power source ideal for both field and laboratory use. Use 4204 as a reference source when determining sound power output of equipment by various comparison methods including ISO 3741, survey methods per ISO 3747, and measuring environmental correction K2 when determining sound power per ISO 3744. It also can be used in the field of building acoustics to determine the sound absorption and the sound insulation of a room. Type 4204 provides 95 dB nominal A-weighted SPL re 1 pW @ 60 Hz line frequency and also fulfils ISO 3745 and ISO 6926 for calibrated sound power sources.

Full specs from manufacturer

Rental Includes

  • AC Power Cord
  • 6.3 A Fuse
  • 2x 12.5 A Fuses
  • Calibration